We help our customers rebuild livesTM
Unser Portfolio im Bereich Traumatologie und Extremit盲ten bietet Ihnen qualitativ hochwertige Implantate f眉r die Versorgung von Frakturen der langen und kurzen Knochen, sowie f眉r den Gelenkersatz im Bereich der Extremit盲ten.
T2 Alpha Tibia Nailing System
T2 Alpha鈥
Tibia Nailing System鈥婭ntramedullary nail for treating proximal, distal, as well as mid-shaft tibial fractures.鈥
T2 Alpha Femur GT
T2 Alpha鈥
Femur Antegrade GT/PF Nailing System鈥
The T2 Alpha Femur Antegrade GT/PF Nailing System introduces a hybrid-implant concept, providing you with versatile locking configurations in a consolidated implant offering. This enhanced design will continue to offer both simplicity and efficiency while allowing you to achieve more with less.鈥
T2 Alpha Femur retrograde
T2 Alpha鈥
Femur Retrograde Nailing System&苍产蝉辫;鈥
Stryker is the market leader in intramedullary nailing. For decades, we've been creating solutions that improve treatment and set new standards. &苍产蝉辫;鈥
九色视频 customers needed intraoperative adaptability and security in a nailing solution, and that's what our system provides. Created with a redefined nail design to treat varying patient needs, advanced locking screws for increased stability, and intuitive instrumentation, the T2 Alpha Femur Retrograde Nailing System delivers a new level of innovation.鈥
Gef眉hrte distale Verriegelung
Das distale T2 Alpha Zielger盲t bietet Chirurgen ein reproduzierbares und konsistentes Verfahren f眉r die distale Schraubenverriegelung.
Weniger Lagerbestand und Lagerplatz
Mit T2 Alpha wird ein Implantatkonzept eingef眉hrt, das Chirurgen vielseitige Verriegelungskonfigurationen in einer konsolidierten Implantatl枚sung bietet, sodass sie mit weniger mehr erreichen k枚nnen.
Schnellere Identifizierung und Pr盲sentation von Implantaten
Eine spezielle H眉lle erm枚glicht eine ber眉hrungslose Handhabung des Implantats.
Mehr Behandlungsoptionen
Mit T2 Alpha werden erweiterte Verriegelungsschrauben eingef眉hrt, die als Alternative zu den IMN-Verriegelungsschrauben verwendet werden k枚nnen. Erweiterte Verriegelungsschrauben sind besonders dann zu verwenden, wenn die Knochenqualit盲t schlecht ist, sowie in anderen F盲llen, in denen Achsstabilit盲t gew眉nscht ist 4
Entwickelt, um die Implantatplatzierung zu erleichtern5
T2 Alpha Femur N盲gel mit SOMA Design haben einen l盲ngenabh盲ngigen Kr眉mmungsradius, d. h., mit zunehmender L盲nge des Nagels vergr枚脽ert sich auch der Kr眉mmungsradius.
VariAx2 Wrist Specific
痴补谤颈础虫2鈥
Wrist Fragment Specific&苍产蝉辫;鈥婽he VariAx 2 Distal Radius System is indicated for the treatment of fractures, non-unions, malunions and deformities of the distal radius.鈥
痴补谤颈础虫2鈥
Mini Fragment 鈥 Your toolbox鈥
The VariAx 2 Mini Fragment plating system features a complete range of low profile plate and screw options in 2.0mm, 2.4mm and 2.7mm modules. Plates utilize SmartLock variable angle locking technology which permits polyaxial screw placement. T8 locking screws may be angled +/- 15潞 in any direction for up to a 30潞 cone. T6 locking screws may be angled +/- 10潞 in any direction for a total of 20潞.
鈥婸lates featured in this system include a variety of broad and narrow locking plates which offer both variable angle locking and compression capabilities. The system also includes profile plates, which are designed to facilitate fracture reduction.鈥
The system utilizes a streamlined and easy to use platform which includes instrument options designed for procedural efficiency. &苍产蝉辫;鈥
Asnis PRO
Cannulated Screw&苍产蝉辫;鈥婽he Asnis III and Asnis PRO 脴6.5 and 脴8.0mm Cannulated Screws are intended for:
PRO
Beckenrepositions- und Osteosynthese-Plattensystem
Anatomische Platten und spezifisches Instrumentarium f眉r die Freilegung, Reposition und Fixierung von Becken- und H眉ftgelenkpfannenfrakturen. Passgenaue Plattierung. Mit besonderem Schwerpunkt auf der Freilegung und Reposition ist das PRO-System einzigartig konstruiert. Um weniger invasive Techniken, wie den anterioren intrapelvinen Zugang zu erleichtern, bei dem das Arbeiten in einem tiefen, engen Raum besondere chirurgische Herausforderungen darstellen kann.8
Hoffmann LRF
Zirkul盲re externe Fixierung der n盲chsten Generation
Basierend auf der langj盲hrigen Tradition der Einfachheit des urspr眉nglichen Hoffmann-Fixateurs bietet das Hofmann LRF-Design eine neue Vielseitigkeit, die den heutigen biologischen Rekonstruktionsmethoden entspricht.
Prophecy庐 滨苍蹿颈苍颈迟测庐 Resect-Through Guides
Prophecy庐 滨苍蹿颈苍颈迟测庐鈥
Resect-Through Guides鈥婤y utilizing the preoperative planning capabilities of the Prophecy system, time-consuming interoperative steps such as determining alignment, choosing implant size, and reliance on fluoroscopic guidance are potentially all reduced. Prophecy guides are designed to match the patient鈥檚 anatomy and fit securely into position, setting resection guide locations according to component alignment determined preoperatively. It鈥檚 time to start optimizing your surgeries by incorporating these guides into your Prophecy plans.鈥婸rophecy Resect-Through Guides provide:鈥
滨苍蹿颈苍颈迟测庐
滨苍蹿颈苍颈迟测庐鈥
Total Ankle System
&苍产蝉辫;鈥婭mprove long term fixation鈥
Adaptis庐 3D printed, porous metal components are designed to act as a scaffold that facilitates bone ingrowth as early as four weeks.鈥
Increase initial stability鈥
Increased initial implant stability through greater friction at the bone to implant interface.
鈥婭mprove wear resistance鈥
Everlast庐 highly cross-linked polyethylene inserts improve wear resistance by up to 26%.鈥
VariAx 2 with Anchorage 2 CP
VariAx庐 2 Plating System鈥
Anchorage庐 2 CP
鈥婣nchorage 2 CP was designed to provide a complementary modular system for indication-specific, reconstructive and trauma procedures of the foot and ankle.鈥
The Anchorage 2 CP Plating System is composed of four pre-contoured, anatomic locking plates. These new plates feature a Cross Plate (CP) hole that allows partially threaded CP screws (either T8 3.6mm or T10 4.1mm) to compress across the fusion site. All other plate holes feature SMARTLock technology which allows for locking screw insertion in any direction up to 15藲. Each Anchorage 2 CP foot plate is low profile (1.5mm) to minimize soft tissue irritation.:
Tornier Perform庐
Humeral Stem&苍产蝉辫;鈥
Refined. Reproducible. Ready.鈥
搁别蹿颈苍别诲鈥
The Tornier Perform Humeral Stem was designed utilizing Blueprint 3D Planning Software and real-world clinical experience in shoulder arthroplasty to create patient-optimized solutions.鈥
搁别辫谤辞诲耻肠颈产濒别鈥
Intuitive instrumentation designed to offer consistent flow in the operating room and a variety of humeral options allowing to repeat your surgical plan, case after case.
鈥婻别补诲测鈥
Backed by the Blueprint 3D Planning Software and the Tornier Perform glenoid portfolio, the Tornier Perform Humeral Stem provides clinical solutions, from simple to complex cases.鈥
Blueprint
&苍产蝉辫;鈥
Digital Technologies鈥婤y merging software with implant designs, clinical outcomes, artificial intelligence and augmented reality, Blueprint is just getting started changing the future of shoulder arthroplasty.鈥
Aequalis Flex Revive
Remove. Rebuild. Restore.
鈥婻别尘辞惫别鈥
Universal instrumentation designed specifically for shoulder applications.
鈥婻别产耻颈濒诲鈥
Surgeons have control of height, version and fixation with system modularity and comprehensive trialing instrumentation鈥.
Restore&苍产蝉辫;鈥
Designed for restoration of stability and function from successful humeral and glenoid reconstruction鈥
Aequalis Reversed II
Remove. Rebuild. Restore.鈥
Biomechanics of the Aequalis Reversed II prosthesis is designed for:鈥
Kontakt
References
1. Caruso, G., et al. 鈥淎 Six-Year Retrospective Analysis of Cut-out Risk Predictors in Cephalomedullary Nailing for Pertrochanteric Fractures.鈥 Bone & Joint Research, vol. 6, no. 8, 2017, pp. 481鈥488.
2. Kuhl, M., Beimel, C. (2017). Precise lag screw placement with the use of a novel computer assisted surgery system during cephalomedullary nailing. Poster presented at 2017 OTA Annual Meeting
3. ADAPT for Gamma3 Instructions for Use ADA-IFU-1 Rev 2, 04-2018
4. T2 Alpha Femur Antegrade GT Nailing System Operative Technique, T2-ST-25_Rev-3, 03-2019.
5. Anatomical compliance of T2 Alpha. T2-WP-5
6. SmartLock technology is licensed from Prof. Wolter, Hamburg, Germany
7. BML98-010 Titanium and its alloys in traumatology, Stryker (Osteo) BML test report
8. PRO System Design Rationale, PRO-DR-1_Rev-1, 10-2019.
9. AxSOS 3 Titanium Proximal Lateral Tibia Locking Plate System Operative technique - Targeting instrumentation AxSOS-ST-50 Rev 6, 10-2019
10. AxSOS 3 Titanium DIstal Lateral Femur Locking Plate System Operative technique - Targeting instrumentation. AxSOS-ST-46 Rev 6, 10-2019
11. Biomechanics and SOMA White Paper Portfolio. OT-BR-19_Rev-1, 08-2018